Tarrant County Public Health
5001 N. Riverside Dr., Suite 105, Fort Worth, Texas 76137 | Visit Official Website

MARRIOTT DALLAS FORT WORTH WESTLAKE

1301 SOLANA BLVD BLDG 3 WESTLAKE, TX 76262

Public Swimming Pool/Spa Inspection Report | Routine

October 2, 2020
Demerits & Grade: Grade:
Observations & Corrective Actions

35: Failure to properly ground the pump

39: Ensure all pipes are properly labeled

51: Unable to demonstrated under water light are in proper working condition

52: unable to demonstrate GFCi on under water lights are in proper working condition

53:

113: Lack of properly working self latching gates

Additional Comments

Correct all finding call back to schedule reinspect to obtain authorization to reopen the pool to the public

Observations
Swimming Pool
IN
1 Chlorine (1-8 ppm) Bromine (2.5-12ppm)
Compliant
Observations
IN
2 pH (7.0 - 7.8)
Compliant
Observations
IN
3 Cyanuric acid (100 ppm or less)
Compliant
Observations
IN
4 Deck & sidewall depth markers permanent with 4" numbers.
Compliant
Observations
IN
5 Markers at max. & min. depth, breakpoint & 2' depth intervals.
Compliant
Observations
IN
6 Minimum 2 entry exits & max user load sign provided.
Compliant
Observations
IN
7 Depth markers no more than 25 feet apart.
Compliant
Observations
IN
8 Depth markers - feet and / or inches 4" letters.
Compliant
Observations
Suction Outlets (Main Drains)
IN
29 Suction outlet cover(s)/grate(s) intact and in place
Compliant
Observations
IN
30 Single suction outlet - SVRD or AVS installed/maintained.
Compliant
Observations
IN
31 Vacuum outlet with cover and auto-latch or filled in.
Compliant
Observations
IN
33 Suction outlet VGBA / ASME/ANSI compliant & extra main drain cover.
Compliant
Observations
IN
34 Single or Dual main drain(s) and minimum 3 feet apart.
Compliant
Observations
Mechanical
OUT
35 Pump functioning.
Observed
Observations
IN
36 Filter on pre- 10/01/99 pool or spa functioning
Compliant
Observations
IN
37 Pump vacuum / inlet/ outlet gauges & flow meter.
Compliant
Observations
OUT
39 Exposed piping labeled to identify function & flow direction.
Observed
Observations
IN
40 Filter on post-10/01/99 pool or spa functioning
Compliant
Observations
IN
41 Strainer on pump.
Compliant
Observations
Operation, Water Quality & Structural Design
IN
42 DPD test kit.
Compliant
Observations
IN
43 Automatic sanitizer dispenser installed and operational.
Compliant
Observations
IN
44 Pool components not maintained/damaged.
Compliant
Observations
IN
45 Water free/clear of algae, debris & main drains of pool/spa visible.
Compliant
Observations
IN
46 Skimmer basket debris free & not used to dispense sanitizer.
Compliant
Observations
IN
47 Skimmer cover, weir, and basket intact/functioning.
Compliant
Observations
IN
48 Pool / Spa bottom and sides light color or white.
Compliant
Observations
IN
49 Adequate hand holds or hand rails and ladder spacing in compliance.
Compliant
Observations
IN
50 1 x 1 stripe on leading edge of underwater / swimout steps.
Compliant
Observations
Electrical
OUT
51 Provided lights adequate/working in pool/spa.
Observed
Observations
OUT
52 GFCIs installed/functioning & electrical outlet(s) with GFCIs.
Observed
Observations
OUT
53 Pump(s) grounded and bonded.
Observations
IN
54 Service electrical disconnect w/in sight of pool / spa equipment.
Compliant
Observations
Fill Water/Drinking Water
IN
55 Return inlets adequate & fill water potable supply.
Compliant
Observations
IN
56 Water distribution system protected against backflow/airgap installed.
Compliant
Observations
IN
57 Over-the-rim fill spout with secure soft pliable end.
Compliant
Observations
IN
58 Drinking water fountain available.
Compliant
Observations
Specific Safety Features - No Diving Markers & Transition Line
IN
59 Min. 2-4" "NO DIVING" letters & symbol no more than 25' apart.
Compliant
Observations
IN
60 4" x 4" line on bottom at transition from shallow to deep.
Compliant
Observations
Specific Safety Features - Signage
IN
61 Sign(s) visible to pool / spa user in all areas of pool / spa yard.
Compliant
Observations
IN
62 NO DIVING - 4" letters and symbol.
Compliant
Observations
IN
63 WARNING-NO LIFEGUARD ON DUTY - 4" letters.
Compliant
Observations
IN
64 Children Should Not Use Pool w/o Adult Supervision - 2" letters.
Compliant
Observations
IN
65 IN CASE OF EMERGENCY - DIAL 911 - 1" letters.
Compliant
Observations
IN
66 Phone location sign visible in pool / spa yard.
Compliant
Observations
Specific Safety Features - Safety Equipment
IN
67 Min 12' non-conductive pole within 20' of pool.
Compliant
Observations
IN
68 USCG ring buoy w/ throw rope within 20' of pool.
Compliant
Observations
IN
69 Emergency phone location sign on pool / spa gate (if required).
Compliant
Observations
IN
70 Emergency phone w/in 200' & not answered by onsite office.
Compliant
Observations
IN
71 Emergency phone functioning.
Compliant
Observations
Bathhouse & Sanitary Facilities
IN
88 Facilities provided, clean and sanitary.
Compliant
Observations
IN
89 Mirror shatter resistant & soap dispenser metal or plastic.
Compliant
Observations
IN
90 Toilet paper & holder provided.
Compliant
Observations
IN
91 Single use towels or hand dryer provided.
Compliant
Observations
IN
92 Covered waste receptacles.
Compliant
Observations
IN
93 Floor slip resistant & sloped to floor drains.
Compliant
Observations
IN
94 Private gender specific facilities.
Compliant
Observations
Glass Containers and Food
IN
95 No glass containers in pool / spa yard.
Compliant
Observations
IN
96 Trash containers provided.
Compliant
Observations
Gas Chlorination
NA
97 Meets minimum standards.
Compliant
Observations
ALL POOLS AND SPAS SUBJECT TO HSC 757
IN
112 Minimum 48 - inch height.
Compliant
Observations
OUT
113 Gate(s) / door(s) self-closing and self-latching.
Observed
Observations
IN
114 Gate(s) / door(s) not propped open.
Compliant
Observations
IN
115 Openings in chain link fabric less than 2 - 1/4".
Compliant
Observations
IN
116 Latch must either be outside & minimum 60" above the ground; or
Compliant
Observations
IN
117 Latch must be inside only & 3" below top of gate / door; and
Compliant
Observations
IN
118 No openings exceeding 1/2" w/in 18" of latch.
Compliant
Observations
IN
119 Latch min. 42" above ground & opens w/ key, card, or comb.
Compliant
Observations
IN
120 Horizontals at least 36" apart w/gaps less than 4".
Compliant
Observations
IN
121 No structures within 36" allowing fence to be scaled.
Compliant
Observations
IN
122 After 01/01/1994 horizontals less than 45" apart and no gaps greater than 1 - 3/4"; or
Compliant
Observations
IN
123 After 01/01/1994 horizontals min. 45" apart/gaps less than 4".
Compliant
Observations
IN
124 No chain link after 01/01/94.
Compliant
Observations
IN
125 Windows in wall(s) permanently closed after 01/01/1994.
Compliant
Observations
IN
126 After 1/01/1994 gate(s) / door(s) open outward & can be locked.
Compliant
Observations
IN
127 No fence cutouts w/gaps greater than 1 - 3/4" after 01/01/94.
Compliant
Observations
LOCAL REQUIREMENTS
IN
128 Operator certification (Class C Pools, Spas) current and available
Compliant
Observations
IN
129 Operation Log: Chemical and fence/gate report meet requirements.
Compliant
Observations
IN
130 Permit current, conspicuously posted.
Compliant