MARRIOTT DALLAS FORT WORTH WESTLAKE

1301 SOLANA BLVD BLDG 3 WESTLAKE, TX 76262

Public Swimming Pool/Spa Inspection Report | Follow-Up

September 6, 2024
Demerits & Grade: Grade:
Observations & Corrective Actions

44: Observd broken and chipped deck flooring around the pool.
Corrective Actions: Must repair broken deck flooring.

47: Observed missing weirs in the skimmers throughout the pool.
Corrective Actions: Must repair/replace weirs.

56: Observed back wash pipe without a proper air gap.
Corrective Actions: Must have back wash pipe properly plumbed with a proper air gap.

57: Observed metal fill spout end slightly exposed underneath soft covering.
Corrective Actions: Must have entire fill spout with a soft pliable end.

61: Observed the following statements not provided on the pool rules signage. Hours of operation not in 1 inch lettering. Maximum used load statement not in 2 inch lettering. “PETS IN THE POOL ARE PROHIBITED” in 2 inch lettering. “DO NOT SWIM IF YOU HAVE BEEN ILL WITH DIARRHEA WITHIN THE PAST 2 WEEKS” in minimum 2 inch lettering. “CHANGING DIAPERS WITHIN 6 FEET OF THE POOL IS PROHIBITED” in minimum 2 inch lettering. “GLASS ITEMS ARE NOT ALLOWED IN THE POOL YARD” in minimum 2 inch lettering. “PERSONS UNDER THE AGE OF 14 MUST NOT BE IN THE POOL WITHOUT ADULT SUPERVISION” in minimum 2 inch lettering.
Corrective Actions: Must have the required pool statements on the pool rules signage.

101: Observed gaps greater than 4 inches at every other fence post gap around the entire pool enclosure.
Corrective Actions: Must have gaps less than 4 inches.

102: Observed a hand rail less than 36 inches away from the fence.
Corrective Actions: Must have structures at least 36 inches away from the fence.

Additional Comments

Okay to open per Tarrant County Public Health. Must repair light as soon as a light replacement has been received. Pool operator provided me proper documentation regarding the pool light not being an electrical hazard when lights are tested on the GFCI. See attached document.

Observations
Swimming Pool
IN
1 Chlorine (1-8 ppm) Bromine (2.5-12ppm)
Compliant
Observations
Suction Outlets (Main Drains)
IN
29 Suction outlet cover(s)/grate(s) intact and in place
Compliant
Observations
IN
32 Equalizer outlet(s) with approved cover or sealed.
Compliant
Observations
IN
33 Suction outlet VGBA / ASME/ANSI compliant & extra main drain cover.
Compliant
Observations
Mechanical
IN
37 Pump vacuum / inlet/ outlet gauges & flow meter.
Compliant
Observations
IN
39 Exposed piping labeled to identify function & flow direction.
Compliant
Observations
Operation, Water Quality & Structural Design
OUT
44 Pool components not maintained/damaged.
Observed
Observations
OUT
47 Skimmer cover, weir, and basket intact/functioning.
Observed
Observations
Electrical
IN
51 Provided lights adequate/working in pool/spa.
Compliant
Observations
Fill Water/Drinking Water
OUT
56 Water distribution system protected against backflow/airgap installed.
Observed
Observations
OUT
57 Over-the-rim fill spout with secure soft pliable end.
Observed
Observations
Specific Safety Features - Signage
OUT
61 Sign(s) visible to pool / spa user in all areas of pool / spa yard.
Observed
Observations
Specific Safety Features - Safety Equipment
IN
68 USCG ring buoy w/ throw rope within 20' of pool.
Compliant
Observations
Class C, Class D, and Day Camp Pools & Spas Not Subject to HSC 757
OUT
101 Openings in or under fence do not allow passage of 4" sphere.
Observed
Observations
OUT
102 No structures within 36" allowing fence to be scaled.
Observed