Tarrant County Public Health
5001 N. Riverside Dr., Suite 105, Fort Worth, Texas 76137 | Visit Official Website

MARRIOTT DALLAS FORT WORTH WESTLAKE

1301 SOLANA BLVD BLDG 3 WESTLAKE, TX 76262

Public Swimming Pool/Spa Inspection Report | Routine

September 28, 2022
Demerits & Grade: Grade:
Observations & Corrective Actions

Additional Comments

OK TO REOPEN SPA.

Observations
Swimming Pool
NA
1 Chlorine (1-8 ppm) Bromine (2.5-12ppm)
Compliant
Observations
NA
2 pH (7.0 - 7.8)
Compliant
Observations
NA
3 Cyanuric acid (100 ppm or less)
Compliant
Observations
NA
4 Deck & sidewall depth markers permanent with 4" numbers.
Compliant
Observations
NA
5 Markers at max. & min. depth, breakpoint & 2' depth intervals.
Compliant
Observations
NA
6 Minimum 2 entry exits & max user load sign provided.
Compliant
Observations
NA
7 Depth markers no more than 25 feet apart.
Compliant
Observations
NA
8 Depth markers - feet and / or inches 4" letters.
Compliant
Observations
Wade Pool
NA
9 Chlorine (1-8 ppm) Bromine (2.5-12 ppm)
Compliant
Observations
NA
10 pH (7.0 - 7.8)
Compliant
Observations
NA
11 Cyanuric acid (100 ppm or less):
Compliant
Observations
NA
12 Deck & sidewall depth markers permanent with 4" numbers.
Compliant
Observations
NA
13 Depth markers no more than 25 feet apart.
Compliant
Observations
NA
14 Depth markers - feet and / or inches 4" letters.
Compliant
Observations
NA
15 Wade pool 15 feet from shallow / 35 feet from deepwater areas.
Compliant
Observations
NA
16 Wade pool fenced separately from pool / spa.
Compliant
Observations
NA
17 Wade pool w/independent circulatory / sanitization system.
Compliant
Observations
Spa
IN
18 Cholrine (2-8ppm) Bromine (4.5 - 12ppm)
Compliant
Observations
IN
19 pH (7.0 - 7.8)
Compliant
Observations
IN
20 Cyanuric acid (100 ppm or less)
Compliant
Observations
IN
21 Temperature 104° or less / Spa thermometer available to users.
Compliant
Observations
IN
22 Emergency shutoff in sight & minimum 5 ft. away.
Compliant
Observations
IN
23 Maximum user load limit sign provided.
Compliant
Observations
IN
24 "Do Not Use Spa if Temp. Is Above 104° F" - 1 in. letters
Compliant
Observations
IN
25 "Children Should Not Use Spa w/o Adult Supervision" - 2".
Compliant
Observations
IN
26 Minimum 2 permanent deck depth markers with 4" numbers.
Compliant
Observations
IN
27 15 min timer-switch minimum 5 feet away from spa.
Compliant
Observations
IN
28 Depth marker feet and / or inches in 4" letters.
Compliant
Observations
Suction Outlets (Main Drains)
IN
29 Suction outlet cover(s)/grate(s) intact and in place
Compliant
Observations
NA
30 Single suction outlet - SVRD or AVS installed/maintained.
Compliant
Observations
IN
31 Vacuum outlet with cover and auto-latch or filled in.
Compliant
Observations
IN
32 Equalizer outlet(s) with approved cover or sealed.
Compliant
Observations
IN
33 Suction outlet VGBA / ASME/ANSI compliant & extra main drain cover.
Compliant
Observations
IN
34 Single or Dual main drain(s) and minimum 3 feet apart.
Compliant
Observations
Mechanical
IN
35 Pump functioning.
Compliant
Observations
IN
36 Filter on pre- 10/01/99 pool or spa functioning
Compliant
Observations
IN
37 Pump vacuum / inlet/ outlet gauges & flow meter.
Compliant
Observations
NA
38 Heater over 200,000 BTU and not accessible.
Compliant
Observations
IN
39 Exposed piping labeled to identify function & flow direction.
Compliant
Observations
IN
40 Filter on post-10/01/99 pool or spa functioning
Compliant
Observations
IN
41 Strainer on pump.
Compliant
Observations
Operation, Water Quality & Structural Design
IN
42 DPD test kit.
Compliant
Observations
IN
43 Automatic sanitizer dispenser installed and operational.
Compliant
Observations
IN
44 Pool components not maintained/damaged.
Compliant
Observations
IN
45 Water free/clear of algae, debris & main drains of pool/spa visible.
Compliant
Observations
IN
46 Skimmer basket debris free & not used to dispense sanitizer.
Compliant
Observations
IN
47 Skimmer cover, weir, and basket intact/functioning.
Compliant
Observations
IN
48 Pool / Spa bottom and sides light color or white.
Compliant
Observations
IN
49 Adequate hand holds or hand rails and ladder spacing in compliance.
Compliant
Observations
NA
50 1 x 1 stripe on leading edge of underwater / swimout steps.
Compliant
Observations
Electrical
IN
51 Provided lights adequate/working in pool/spa.
Compliant
Observations
IN
52 GFCIs installed/functioning & electrical outlet(s) with GFCIs.
Compliant
Observations
IN
53 Pump(s) grounded and bonded.
Compliant
Observations
IN
54 Service electrical disconnect w/in sight of pool / spa equipment.
Compliant
Observations
Fill Water/Drinking Water
IN
55 Return inlets adequate & fill water potable supply.
Compliant
Observations
IN
56 Water distribution system protected against backflow/airgap installed.
Compliant
Observations
IN
57 Over-the-rim fill spout with secure soft pliable end.
Compliant
Observations
IN
58 Drinking water fountain available.
Compliant
Observations
Specific Safety Features - No Diving Markers & Transition Line
IN
59 Min. 2-4" "NO DIVING" letters & symbol no more than 25' apart.
Compliant
Observations
IN
60 4" x 4" line on bottom at transition from shallow to deep.
Compliant
Observations
Specific Safety Features - Signage
IN
61 Sign(s) visible to pool / spa user in all areas of pool / spa yard.
Compliant
Observations
IN
62 NO DIVING - 4" letters and symbol.
Compliant
Observations
IN
63 WARNING-NO LIFEGUARD ON DUTY - 4" letters.
Compliant
Observations
IN
64 Children Should Not Use Pool w/o Adult Supervision - 2" letters.
Compliant
Observations
IN
65 IN CASE OF EMERGENCY - DIAL 911 - 1" letters.
Compliant
Observations
IN
66 Phone location sign visible in pool / spa yard.
Compliant
Observations
Specific Safety Features - Safety Equipment
IN
67 Min 12' non-conductive pole within 20' of pool.
Compliant
Observations
IN
68 USCG ring buoy w/ throw rope within 20' of pool.
Compliant
Observations
IN
69 Emergency phone location sign on pool / spa gate (if required).
Compliant
Observations
IN
70 Emergency phone w/in 200' & not answered by onsite office.
Compliant
Observations
IN
71 Emergency phone functioning.
Compliant
Observations
Class A & B Pools/ Spas
NA
72 Operator license(s) current and available.
Compliant
Observations
NA
73 Water tested every 2 hours pool / spa is in use (see log).
Compliant
Observations
NA
74 Rope and float line at shallow to deep transition.
Compliant
Observations
NA
75 Dressing / sanitary facilities provided.
Compliant
Observations
Lifeguard / Second Responder
NA
76 Lifeguard(s) provided as required (Class A & B/slide/diving board).
Compliant
Observations
NA
77 Current certification(s) available.
Compliant
Observations
NA
78 Second responder on duty.
Compliant
Observations
NA
79 Sufficient number of rescue tubes provided.
Compliant
Observations
NA
80 Backboard with 3 tie-down straps & head immobilizer.
Compliant
Observations
NA
81 First aid kit with anti-disease transmission capabilities.
Compliant
Observations
NA
82 Sufficient in-service training provided (60 minutes / week).
Compliant
Observations
Diving Facilities
NA
83 Distance between multiple boards minimum 10 feet.
Compliant
Observations
NA
84 Lifeguard chair(s) at least 4 feet above deck to view diving area.
Compliant
Observations
NA
85 Boards / platforms 1/2 - 1 M with single guard & handrails.
Compliant
Observations
NA
86 Boards / platforms over 1 M with 2 / dual guard & handrails.
Compliant
Observations
NA
87 Diving board(s) properly labeled.
Compliant
Observations
Bathhouse & Sanitary Facilities
NA
88 Facilities provided, clean and sanitary.
Compliant
Observations
NA
89 Mirror shatter resistant & soap dispenser metal or plastic.
Compliant
Observations
NA
90 Toilet paper & holder provided.
Compliant
Observations
NA
91 Single use towels or hand dryer provided.
Compliant
Observations
NA
92 Covered waste receptacles.
Compliant
Observations
NA
93 Floor slip resistant & sloped to floor drains.
Compliant
Observations
NA
94 Private gender specific facilities.
Compliant
Observations
Glass Containers and Food
IN
95 No glass containers in pool / spa yard.
Compliant
Observations
IN
96 Trash containers provided.
Compliant
Observations
Gas Chlorination
NA
97 Meets minimum standards.
Compliant
Observations
Class C, Class D, and Day Camp Pools & Spas Not Subject to HSC 757
NA
98 Minimum 48 - inch height.
Compliant
Observations
NA
99 Gate(s) / door(s) self-closing and self-latching.
Compliant
Observations
NA
100 Gate(s) / door(s) not propped open.
Compliant
Observations
NA
101 Openings in or under fence do not allow passage of 4" sphere.
Compliant
Observations
NA
102 No structures within 36" allowing fence to be scaled.
Compliant
Observations
NA
103 Opening hardware min. 42" above ground.
Compliant
Observations
NA
104 Post 10/01/99 no chain link fence after 9/1/2004.
Compliant
Observations
NA
105 Post-10/01/99 gate(s) / door(s) open outward & can be locked.
Compliant
Observations
NA
106 Post- 10/01/99 No building door or gate opening directly into pool yard or spa yard that opens outside enclosure. No window opening in pool/spa enclosure.
Compliant
Observations
CLASS A & B AND ALL RESIDENTIAL YOUTH CAMPS
NA
107 Minimum fence height 6 feet.
Compliant
Observations
NA
108 Fence designed to be difficult to climb.
Compliant
Observations
NA
109 Openings in or under fence do not allow passage of 4" sphere.
Compliant
Observations
NA
110 Building door or gate does not open outside pool / spa enclosure.
Compliant
Observations
NA
111 Gate(s) / Door(s) continuously & directly supervised or locked.
Compliant
Observations
ALL POOLS AND SPAS SUBJECT TO HSC 757
IN
112 Minimum 48 - inch height.
Compliant
Observations
IN
113 Gate(s) / door(s) self-closing and self-latching.
Compliant
Observations
IN
114 Gate(s) / door(s) not propped open.
Compliant
Observations
NA
115 Openings in chain link fabric less than 2 - 1/4".
Compliant
Observations
IN
116 Latch must either be outside & minimum 60" above the ground; or
Compliant
Observations
IN
117 Latch must be inside only & 3" below top of gate / door; and
Compliant
Observations
IN
118 No openings exceeding 1/2" w/in 18" of latch.
Compliant
Observations
IN
119 Latch min. 42" above ground & opens w/ key, card, or comb.
Compliant
Observations
IN
120 Horizontals at least 36" apart w/gaps less than 4".
Compliant
Observations
IN
121 No structures within 36" allowing fence to be scaled.
Compliant
Observations
IN
122 After 01/01/1994 horizontals less than 45" apart and no gaps greater than 1 - 3/4"; or
Compliant
Observations
IN
123 After 01/01/1994 horizontals min. 45" apart/gaps less than 4".
Compliant
Observations
NA
124 No chain link after 01/01/94.
Compliant
Observations
IN
125 Windows in wall(s) permanently closed after 01/01/1994.
Compliant
Observations
IN
126 After 1/01/1994 gate(s) / door(s) open outward & can be locked.
Compliant
Observations
IN
127 No fence cutouts w/gaps greater than 1 - 3/4" after 01/01/94.
Compliant
Observations
LOCAL REQUIREMENTS
IN
128 Operator certification (Class C Pools, Spas) current and available
Compliant
Observations
IN
129 Operation Log: Chemical and fence/gate report meet requirements.
Compliant
Observations
IN
130 Permit current, conspicuously posted.
Compliant