Score & Grade: Grade:
Site ID

8135

Observations & Corrective Actions

1: Chlorine-Free Available: 8.0 ppm

2: pH level: 7.4 Cyanuric Acid: 40 ppm

5: 1. Monthly operational records of emergency telephone test results are not recorded/maintained. OBSERVED NOT MAINTAINED. 2. Weekly pool yard enclosure and gate inspection results are not recorded/maintained. OBSERVED NOT MAINTAINED. 3. Weekly inspection of Ground Fault Circuit Interrupter not recorded/maintained. OBSERVED NOT MAINTAINED.

6: 1. Operational records of tests results are not maintained. OBSERVED NOT MAINTAINED.

12: 1. A filter outlet pressure gauge is not installed on the piping. OBSERVED MISSING GAUGES.

13: 1. Exposed piping is not labeled to identify the piping function and direction of flow.

16: 1. Surface skimmer or parts are missing, broken, damaged or not maintained. OBSERVED MISSING WEIRS.

19: 2. Air Gap for Waste Water Discharge Not Provided: There is a direct mechanical connection between the wastewater disposal system and a drain or re-circulation system.

28: 2. Required Lifeguard Safety Equipment Not Maintained: The pool safety equipment is damaged, broken or is not properly attached or maintained. OBSERVED DAMAGED REACHING POOL.

29: 1. Throwing rope with attached ring buoy is not provided or accessible. OBSERVED THROWING ROPE NOT LOOSELY TIED IN A THROWING POSITION.

38: 1. Adequate "NO DIVING" Sign Not Installed. Properly designed "NO DIVING" signage is not provided.

47: "DO NOT SWIM IF YOU HAVE BEEN ILL WITH DIARRHEA WITHIN THE PAST 2 WEEKS" sign not installed.

50: Install "EXTENDED BREATH HOLDING ACTIVITIES ARE DANGEROUS AND PROHIBITED" sign not installed.

63: 1. Overhead or Underwater Lighting Not Maintained OBSERVED BOTH UNDERWATER LIGHTS NOT FLUSHED TO THE WALL.

78: 1. Adequate Pool & Spa Gates/Doors Not Provided. OBSERVED MAIN GATE AND RIGHT SIDE GATE NOT LATCHING AT 6 INCHES.

79: 1. Openings under fence allow passage of 4" sphere. Adequate Enclosure Not Provided OBSERVED FENCING ON GATE WITH STEP GREATER THAN 4 INCHES, AND SIDES OF FAR SOUTH GATE GREATER THAN 4 INCHES.

84: 1. Climbable structures within 36 inches of pool enclosure. Adequate Enclosure Not Provided. OBSERVED CLIMBABLE TREE.

153: You are hereby notified that you must take immediate action to close and secure your pool to the public until appropriate corrective actions are taken to safeguard the public from the hazards detailed above in this report. CLOSURE DUE TO GAPS IN FENCE, CLIMBABLE TREE, AND UNDERWATER LIGHTS NOT FLUSHED TO THE WALL.

Additional Comments

CLOSURE DUE TO GAPS IN FENCE, CLIMBABLE TREE, AND UNDERWATER LIGHTS NOT FLUSHED TO THE WALL.

CHS- Victoria Uzu 817-480-1775
Victoria.uzu@fortworthtexas.gov

Observations

Chemicals are within the required ranges. Thank you for maintaining good water quality.

OUT
1 Cl residual; Br residual
Observations

Chemicals are within the required ranges. Thank you for maintaining good water quality.

OUT
2 pH (7.0-7.8); CYA
Observations

1. Emergency Telephone operation shall be tested and recorded monthly and be made available to the Director or representative upon request. 2. Weekly inspection of Pool yard enclosure and gates must be recorded. 3. Inspection of working Ground Fault Circuit Interrupter for pool/spa equipment shall be tested and recorded at least one time per week and be made available to the Director or his/her representative upon request.

OUT
5 Operation logs: (GFCI; phone; fence)
Observations

1. When tests are required, operational record of tests results shall be maintained for two years and shall be made available to the Director or his/her representative upon request.

OUT
6 Operation logs: (chemicals)
Observations

1. A filter outlet pressure gauge shall be installed on the piping.

OUT
12 Inlet, outlet gauges installed/functioning.
Observations

1. Exposed piping shall be labeled to identify the piping function and direction of flow. The name of the liquid or gas and arrows indicating direction of flow shall be permanently indicated on the pipe.

OUT
13 Exposed piping labeled. Valves labeled.
Observations

1. Damaged or missing skimmer systems or overflow devices or parts (weirs, covers, baskets, etc.) shall be repaired or replaced.

OUT
16 Skimmer cover, weir and basket intact/functioning.
Observations

2. Backwash or drain water shall be discharged through an air gap at least two times the diameter of the discharge pipe located above the overflow level. A splash screen barrier can be used to prevent water splashing.

OUT
19 Adequate airgap installed at backwash to sanitary sewer.
Observations

2. The pool safety equipment shall be repaired or properly attached and maintained. At each Class C pool, one light, strong, non-telescoping, non-conducting 12 foot long or longer pole with attached body hook or shepherd's crook and one throwing rope that reaches at least 2/3 the maximum pool width with firmly attached 15 - 24 inch Coast Guard approved ring buoy shall be mounted in a conspicuous place within 20 feet of the pool. Both shall be provided for each 2,000 square feet of water surface and shall be accessible.

OUT
28 Minimum 12' non-conductive reaching pole within 20' of pool.
Observations

1. One throwing rope that reaches at least 2/3 the maximum pool width with firmly attached 15 - 24 inch Coast Guard approved ring buoy shall be mounted in a conspicuous place within 20 feet of the pool. One shall be provided for each 2,000 square feet of water surface and shall be accessible.

OUT
29 USCG ring buoy w/throw rope within 20' of pool.
Observations

1. Install "NO DIVING" Wording and Symbol Warning Signs: At class C & D pools where no lifeguard is provided, a securely mounted sign which is readily visible to swimmers with the warning words "NO DIVING" and the international symbol for no diving with letters at least four (4) inches high shall be placed in plain view.

OUT
38 "NO DIVING" 4" letters and 4" no diving symbol
Observations

A securely mounted sign with the words "DO NOT SWIM IF YOU HAVE BEEN ILL WITH DIARRHEA WITHIN THE PAST 2 WEEKS" with letters at least two inches high shall be places in a plain view and shall be readily visible to pool and spa users.

OUT
47 "DO NOT SWIM IF YOU HAVE BEEN ILL WITH DIARRHEA WITHIN THE PAST 2 WEEKS" - 2" letters
Observations

A securely mounted sign with the words "EXTENDED BREATH HOLDING ACTIVITIES ARE DANGEROUS AND PROHIBITED" with letters at least two inches high shall be places in a plain view and shall be readily visible to pool and spa users.

OUT
50 "EXTENDED BREATH HOLDING ACTIVITIES ARE DANGEROUS AND PROHIBITED" - 2" letters
Observations

1. Overhead or underwater lighting must be safely or properly maintained.

OUT
63 Provided lights adequate/working. (in pool)
Observations

1. All gates or doors for pools and spas (other than new Class A & B pools) shall be lockable and equipped with self-locking and self-latching devices. The gates or doors shall meet the requirements of Ch. 757 or the State law as defined.

OUT
78 Gate(s) self-closing and self-latching & not propped open
Observations

1. The enclosure for all pools and spas which may include a fence, portion of a building, wall or other durable enclosure not associated with private premises shall have a minimum effective perpendicular height of four (4) feet measured from the deck surface on the outside of the fence. Planters or other climbable structures shall not be within 36 inches of the outside fence. The fence, gates and doors shall meet the requirements of the applicable state law or city ordinance as defined.

OUT
79 No openings under fence allow passage of 4" sphere
Observations

1. Install Adequate Enclosure: The enclosure for all pools and spas (other than new Class A & B pools) which may include a fence, portion of a building, wall or other durable enclosure shall comply with the appropriate state law or city ordinance as defined. Planters or other climbable structures shall not be within 36 inches of the outside fence.

OUT
84 No structures within 36" allowing fence to be scaled
Observations

OUT
152 Garbage and Refuse properly disposed; facilities maintained
Compliant
Observations

Re-inspection fee waived. Serious health violations were identified during today's health inspection. You must close and secure your pool immediately to the public until appropriate corrective actions are completed. The owner/operator must take immediate action to correct the hazards. Contact the Consumer Health Specialist named in this report to set up an appointment for a re-inspection. The closed facility must meet minimum standards before it can be re-opened.

OUT
153 CLOSURE